CONTENTS BACK PRINT NOT APPLICABLE NOT APPLICABLE EMERGENCY PROCEDURES

Main Freezes/Resets

This page is selectable from the Freeze/Resets tab suite and allows you to suspend and restart all or some of the simulated systems, and to reset the main aircraft systems to normal operating conditions.

NOTE: IOS remains operational during all freeze states.

Freezes

Total Freeze Complete freeze of all simulated systems, except FMS. Simulator returns to level position and sound system is inhibited. Inputs to simulation from IOS and cockpit controls have no effect.
Flight Freeze Freezes aerodynamic parameters (aircraft speed, attitude, altitude and geographical position). Aircraft systems remain operational.
Position Freeze  Freezes aircraft at current geographical location. All other aerodynamic and aircraft systems remain operational.
Altitude Freeze  Freezes aircraft altitude at current setting. All other aerodynamic and aircraft systems remain operational.
Fuel Freeze Freezes fuel quantities at current value. Engine fuel flows unaffected, but no fuel depletion occurs.

Resets

Master Reset Resets all systems and temperatures defined on the second page to normal operating conditions. Resets all active and armed malfunctions, restores all failed navigational facilities and clears all circuit breaker trip conditions.

NOTE: Popped circuit breakers must be manually reset.

Master Reset also performs:

- IRS Fast Align and EFCS Box Reset

- Deactivates any active Lesson Plans

- Deactivates ATIS Overide Mode

- Removes Altitude, Airspeed and Fly Level Locks

- Clears Windshears, Storms, etc.

Environment Reset No storms, standard atmosphere, no icing conditions, no weather effects, no microburst/wind shear, no wind and no wind gradient, CAVOK, Horizon bright, Runway dry and smooth, visual day conditions, no turbulence, no TCAS, no ground traffic, Airport lighting reset.
ISA Standard Day Reset Selects standard day weather conditions:
Tropopause level: FL 360
QNH: 1013.2 mb
Temperature gradient: -1.98°C/1000 ft
Sea level temperature: 15°C
Delta ISA: 0°C
Weather Scenario Master Reset Deactivates any active scenarios, restores default setings and reactivates defined default scenario.
All Systems Reset Resets all systems defined on the page to normal operating conditions.
All Temps Reset Resets all temperatures defined on the page to normal operating conditions.
Malfunctions, Failed Stations & CBs Reset Resets all active and armed malfunctions and restores all failed radio stations.